Experimental evaluation of energy resolutions for pulsed neutron beam in the KURNS-LINAC

26 Jul 2022, 12:03
12m
Sutter's Fort

Sutter's Fort

Speaker

Mr Yasunori Matsuo (Kindai University)

Description

Energy resolutions of pulsed neutrons are one of the important parameters for nuclear data measurement by TOF method. The energy resolutions are a facility-specific parameters, and has been evaluated experimentally and numerically at various TOF facilities using pulsed neutrons.
KURNS-LINAC is an L-band electron linear accelerator with maximum acceleration voltage of 46 MeV established at Institute for Integrated Radiation and Nuclear Science, Kyoto University. By using a target according to a research purpose, we can use various types of particle beam sources, i.e. neutron, electron, and photon. In addition, the pulsed width of the electron beam can be easily changed. For a pulsed neutron source, a water-cooled tantalum (Ta) target as a photo-neutron target and various moderator are used. A typical neutron flight tube used for nuclear data measurement at KURRI-LINAC is installed in the direction of 135 degree to the LINAC electron beam line, and the neutron flight path from the Ta target to a sample is about 12.7 m.
In this study, experimentally evaluations for the energy resolution of pulsed neutron flux in the neutron path were carried out. The capture gamma-rays from a Ta-181 sample were measured by a BGO detector with a TOF method and the TOF spectra for well-known resonances were obtained. The energy resolution was evaluated by comparing the full width at half maximum of the Ta-181 resonances in the JENDL-4.0. In order to obtain relationships between the energy resolution and the pulsed neutron beam width, the measurements were carried out with the pulsed neutron beam width of 100 nsec, 1 μsec and 4 μsec, respectively. As the experimental results, the energy resolution of neutron energy range from 4 eV to 100 eV corresponding to each pulse width were evaluated. For example, the energy resolution at 4.28 eV (Ta-181 first resonance peak) was about 1.0 % for a pulse width of 4 μsec.

Author

Mr Yasunori Matsuo (Kindai University)

Presentation materials