In proton therapy, Positron Emission Tomography (PET) range verification, which is based on the detection of the short-lived (online monitoring) or the long-lived (offline monitoring) $\beta^{+}$ emitters produced in the body of the patient, has been proved to be a well-suited technique to monitor the beam range $^{[1]}$. This technique requires the comparison of the observed activity distribution with a simulated one using a Monte Carlo code. As the reliability of the simulated activity distribution depends on the accuracy of the underlying cross sections for producing the $\beta^{+}$ emitters of interest $^{[2][3][4]}$, several studies confirm the need for more and better measurements and evaluations $^{[4][5][6]}$. New data related to the production of the short-lived nuclides involved in real-time verification $^{[7][8][9]}$ are especially needed, as there are no data available yet in the energy range of interest, up to 200 MeV.
In this context, we have developed two methods to measure the production cross sections of the mentioned long-lived ($^{11}$C with t$_{1/2}$ = 20.4 min, $^{13}$N with t$_{1/2}$ = 9.97 min and $^{15}$O with t$_{1/2}$ = 122 s) and short-lived ($^{12}$N with t$_{1/2}$ = 11 ms, $^{29}$P with t$_{1/2}$ = 4.14 s and $^{38mK}$ with t$_{1/2}$ = 924 ms) $\beta^{+}$ emitters. The methods are based on the multifoil activation technique combined with dynamic PET scanner imaging that is performed either in-beam (for short-lived $\beta^{+}$ emitters) or outside the irradiation room (for long-lived $\beta^{+}$ emitters). The technique has been first validated at the 18 MeV cyclotron of CNA in Spain $^{[10]}$, and then applied up to a nominal proton beam energy of 200 MeV at the WPE and HIT clinical facilities in Germany; in the first case using a commercial PET/CT scanner for $\beta^{+}$ long-lived emitters and in the latter using a state-of-the-art miniPET made of four i-TED $^{[11][12]}$ detectors for short-lived $\beta^{+}$ emitters. The results from both experimental campaigns will be presented and the relevance of the new data for PET range verification will be discussed.
$^{[1]}$ A. C. Kraan et al., Frontiers in Oncology 5 150 (2015)
$^{[2]}$ U. Oelfke, G. K. Lam and M. S. Atkins, Physics in Medicine and Biology 41 177 (1996)
$^{[3]}$ K. Parodi et al., Physics in Medicine and Biology 52 3369-3387 (2007)
$^{[4]}$ Tárkányi et al. J. Radioanalytical and Nuclear Chemistry. 319 533–666 (2019)
$^{[5]}$ S. España et al., Phys. Med. Biol. 56(9) 2687-2698 (2011)
$^{[6]}$ E. Seravalli et al., Phys. Med. Biol. 57 1659 (2012)
$^{[7]}$ P. Dendooven et al., Phys. Med. Biol. 64 129501 (2019)
$^{[8]}$ H. J. Buitenhuis et al., Phys. Med. Biol. 62 4654 (2017)
$^{[9]}$ I. Ozoemelam et al., Phys. Med. Biol. 65 245013 (2020)
$^{[10]}$ T. Rodríguez-González et al., Rad. Phys. and Chem. 190 109759 (2022)
$^{[11]}$ C. Domingo-Pardo. Nucl. Inst. and Methods A 825 78-86 (2016)
$^{[12]}$ V. Babiano et al., Nucl. Inst. and Methods A 953 163228 (2020)